ebro EBI 25 Wireless Data Logger
ebro EBI 25 wireless temperature and humidity data logger system (EBI 25-T, EBI 25-TE, EBI 25-TX, EBI 25-TH) with radio technology for use in cold stores, warehouses, supermarkets and other environments that need constant monitoring of temperature and/or humidity so that stored goods are protected.
- Features
- Specifications
The starter kit comes complete with remote sensors, wall brackets, interface station and software. Once installed, the system continually monitors the required parameters and transmits the results to the PC (not supplied). Simple to install protection for critical environments.
- Continuous monitoring of all areas where food, pharmaceutical and medical products are produced and stored.
- Avoid loss of goods with the continuous monitoring of all crucial temperature points – 24 hours on 365 days a year.
- Quick intervention before it is too late with a very wide and flexible alarm management (notification via email or acoustical).
- Automatic documentation through automatic recording, storage, and reporting of the measured data. Problems can easily be traced and audit reports can be generated instantly.
- Worldwide access to the measurement data via internet – at any time, any place and any PC with internet and network access. Security is ensured using a login and password.
- Easy handling saves time, efforts and energy.
- Excellent price/performance ratio
- Automatic recording of temperature/humidity data
- Programming and evaluation with PC LED alarm
- Min/max values on display
- Replaceable battery
- Wireless connection 868 MHz
Options: External aerials for extneded range, EBI 25 sensors with penetration probes and more.
Type | EBI 25-T | EBI 25-TE | EBI 25-TX | EBI 25-TH |
Probes | Internal | External | External for very deep temperatures |
Internal: temperature External: humidity |
Measurement range: temperature | -30 °C ... +60 °C | -40 °C ... +85 °C | -200 °C ... +199.9 °C | -30 °C ... +60 °C |
Measurement range: humidity | 0% rH ... 100% rH | |||
Accuracy: temperature | ±0.5 °C (-20 °C ... +40 °C) ±0.8 °C for the remaining measurement range |
±0.5 °C (-20 °C ... +40 °C) ±0.8 °C (-30 °C ... -20 °C and +40 °C ... +60 °C) ±1.5 °C (-40 °C ... -30 °C and +60 °C ... +85 °C) |
±2.0 °C (-200 °C ... -100 °C) ±0.5 °C (-100 °C ... -20 °C) ±0.2 °C (-20 °C ... +60 °C) ±0.5 °C (+60 °C ... +199.9 °C) |
±0.5 °C (-20 °C ... +40 °C) ±0.8 °C for the remaining measurement range |
Accuracy: humidity | ±3 % | |||
Memory capacity | 288 measurements | 288 measurements | 288 measurements | 576 measurements (288 measurements per channel ) |
Sensor | NTC | NTC | Pt 1000 | NTC |
Protection class | IP 67 | IP 67 | IP 67 | IP 20 |
General technical data | |
---|---|
Measurement interval | 1 min. to 24 hours, adjustable |
Radio frequency | 868 MHz |
Battery | 3.6 V lithium (user replaceable) |
Battery lifetime | Up to 2 years, depending on transmission rate |
Storage temperature | -40 °C ... +70 °C |